Glossary
Technical terms and definitions related to D.C. contactors and switching
A
- AC (Alternating Current)
- An electric current that periodically reverses direction, in contrast to direct current (DC) which flows only in one direction.
- Ambient Temperature
- The temperature of the surrounding environment in which equipment operates. Contactors have specified operating temperature ranges.
- Arc
- An electrical discharge that occurs when contacts open or close under load. Arc suppression is critical in contactor design.
- Arc Suppression
- Methods used to extinguish the electrical arc that forms when contacts separate, including magnetic blowout and arc chutes.
- Auxiliary Contacts
- Additional contacts used for signaling or control circuits, not intended for the main load current.
B
- Breaking Capacity
- The maximum current that a contactor can safely interrupt (break) without damage.
- Busbar
- A thick strip of copper or aluminium that conducts electricity within a switchboard, distribution board, or other electrical apparatus.
C
- CCC
- China Compulsory Certification - a mandatory safety mark for products sold in China.
- Coil
- The electromagnetic component that, when energized, creates the magnetic force to close or open the contactor contacts.
- Coil Voltage
- The voltage required to energize the contactor coil and operate the device.
- Contact Bounce
- The unwanted intermittent opening and closing of contacts during switching, which can cause arcing and wear.
- Contact Gap
- The distance between open contacts. A larger gap provides better electrical isolation.
- Contact Resistance
- The electrical resistance at the interface between closed contacts. Lower is better for efficiency.
- Contactor
- An electrically controlled switch used for switching a power circuit, similar to a relay but designed for higher current applications.
- Continuous Current Rating
- The maximum current a contactor can carry continuously without exceeding temperature limits.
D
- DC (Direct Current)
- An electric current that flows in one direction only, as opposed to alternating current (AC).
- Dielectric Strength
- The maximum electric field that a material can withstand without breaking down (becoming conductive).
- DPDT
- Double Pole Double Throw - a switch configuration with two separate circuits, each with two possible output positions.
- Duty Cycle
- The ratio of time a device is operated compared to the total time, often expressed as a percentage.
E
- Electrical Life
- The number of operations a contactor can perform under specified electrical load conditions.
- Emergency Disconnect
- A manual switch designed for rapid disconnection of power in emergency situations.
- Enclosure
- A protective housing for electrical equipment, rated according to the level of protection provided (e.g., IP ratings).
H
- Hermetically Sealed
- Completely airtight, preventing the ingress of moisture and contaminants. Important for harsh environments.
- High Voltage
- In DC systems, typically refers to voltages above 60V, though definitions vary. Albright HV products handle up to 1000V DC.
- Holding Current
- The current required to keep a contactor coil energized after initial pickup.
I
- Inductive Load
- A load that causes current to lag behind voltage, such as motors and transformers. Requires special consideration for switching.
- Inrush Current
- The initial surge of current when a device is first energized, often several times higher than normal operating current.
- IP Rating
- Ingress Protection rating indicating the level of protection against solid objects and liquids (e.g., IP65, IP67).
- ISO 9001
- International standard for quality management systems, demonstrating consistent quality in products and services.
- ISO 14001
- International standard for environmental management systems, demonstrating commitment to environmental responsibility.
M
- Magnetic Blowout
- A method of arc suppression using a magnetic field to stretch and extinguish the arc when contacts separate.
- Make Capacity
- The maximum current that a contactor can safely close (make) without welding or damage to contacts.
- Mechanical Life
- The number of operations a contactor can perform without electrical load (no-load operations).
- Motor Reversing
- A switching configuration using two contactors to reverse the direction of a DC motor.
N
- NO (Normally Open)
- Contacts that are open (not conducting) when the coil is not energized, and close when energized.
- NC (Normally Closed)
- Contacts that are closed (conducting) when the coil is not energized, and open when energized.
O
- Operating Temperature Range
- The range of ambient temperatures within which a device will function correctly.
- Overload
- A condition where current exceeds the rated capacity of a device, potentially causing damage or failure.
P
- Pick-up Voltage
- The minimum coil voltage required to close the contactor contacts from the open position.
- Polarized Contactor
- A contactor designed for current flow in one direction only, often used in battery applications.
- Pull-in Current
- The current required to initially close the contacts of a contactor.
R
- Relay
- An electrically operated switch, typically for lower current applications than contactors.
- Resistive Load
- A load where current and voltage are in phase, such as heating elements. Generally easier to switch than inductive loads.
- RoHS
- Restriction of Hazardous Substances - EU directive limiting the use of specific hazardous materials in electrical equipment.
S
- SPDT
- Single Pole Double Throw - a switch with one input and two possible output connections.
- SPST
- Single Pole Single Throw - a simple on/off switch with one input and one output.
- Stud Terminal
- A threaded bolt connection point for high current cables, common in contactor designs.
- Switching Frequency
- The rate at which a contactor can operate (cycles per hour or minute).
U
- UL
- Underwriters Laboratories - a safety certification organization, UL listing indicates product safety compliance.
V
- Voltage Drop
- The reduction in voltage across a component, such as closed contacts. Lower is better for efficiency.
W
- Welding (Contact)
- Unintended fusing of contacts due to excessive current or arcing, preventing normal operation.